Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR15
Message arg1 rebuild is complete.
Arguments arg1 = physical disk
Detailed
Description
This message is generated after a rebuild completes on a physical disk.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2092
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR16
Message Predictive failure reported for arg1 .
Arguments arg1 = physical disk
Detailed
Description
The physical disk is predicted to fail. Many physical disks contain Self Monitoring
Analysis and Reporting Technology (SMART). When enabled, SMART monitors the
disk health based on indications such as the number of write operations that were
performed on the disk.
Recommended
Response Action
Replace the physical disk. Even though the disk may not have failed yet, it is
strongly recommended that the disk be replaced. Review other messages for
additional information.
922