Reference Guide

Table Of Contents
PDR116
Message Predictive failure reported for arg1
Arguments arg1 = PCIe solid state device name
Detailed
Description
The PCIe Solid-State Drive is predicted to fail. Many physical disks contain Self
Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART
monitors the disk health based on indications such as the number of write
operations that were performed on the disk.
Recommended
Response Action
Back up the data on the device, and contact your service provider for further
instructions.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PDR117
Message The arg1 has turned off because the critical temperature threshold is exceeded.
Arguments arg1 = PCIe solid state device name
Detailed
Description
The PCIe solid state device identified in the message has turned off because the
critical temperature threshold of the device was exceeded.
Recommended
Response Action
Contact your service provider for further instructions.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
919