Reference Guide

Table Of Contents
Recommended
Response Action
Remove and reseat the failed disk. If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 2297
LCD Message Fault detected on drive <number>. Check drive.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PDR1102
Message A predictive failure detected on drive arg1 .
Arguments arg1 = number
Detailed
Description
The controller received a SMART error from the drive. The drive is operational but
needs replacement.
Recommended
Response Action
The drive will need replacement at the next service window.
Category System Health (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 2298
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
908