Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PDR101
Message Global Hot Spare arg1 does not cover all arrays.
Arguments arg1 = PD Name
Detailed
Description
This alert message occurs if there are arrays not protected with a global hot spare.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2209
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR1016
Message Drive arg1 is removed from disk drive bay arg2 .
Arguments arg1 = number, arg2 = bay
Detailed
Description
The controller detected that the drive was removed.
Recommended
Response Action
Verify drive installation. Remove and reseat the failed drive. If the problem persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health (PDR = Physical Disk)
896