Reference Guide

Table Of Contents
Detailed
Description
A low-severity issue is detected in the component identified in the message.
Recommended
Response Action
Remove and reinsert the component identified in the message, and then monitor
the log for a re-occurrence of the issue. If the issue persists, and occurs during
server startup, update the component firmware. If the issue persists and occurs
during OS runtime, restart the server and update the OS drivers for the component
identified in the message.
Category System Health (PCI = PCI Device)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PCI5001
Message A PCIe card carrier containing a PCIe card is inserted in PCIe slot arg1 .
Arguments arg1 = slot number
Detailed
Description
A PCIe card carrier containing a PCIe card is present in the slot identified in the
message. This PCIe card will be enabled when the associated server is turned on or
power cycled.
Recommended
Response Action
Turn on or power cycle the associated server to enable the PCIe card.
Category Configuration (PCI = PCI Device)
Severity Severity 3 (Informational)
Trap/EventID 10611
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * *
883