Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PCI1354
Message A bus correctable error was detected on a component at slot arg1 .
Arguments arg1 = number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device at
the next scheduled service time.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Trap/EventID 2417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PCI1356
Message A bus uncorrectable error was detected on a component at slot arg1 .
Arguments arg1 = number
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the
device.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Trap/EventID 2417
866