Reference Guide

Table Of Contents
Detailed
Description
Unable to get the size or label for selected operating system from the Driver Pack
present in Lifecycle Controller. The driver pack may be corrupt.
Recommended
Response Action
Update the Driver Pack using USC or DUP and rerun the command.
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
OSD21
Message Unable to boot to ISO image.
Detailed
Description
Booting to ISO has failed. Either BIOS was unable to boot to the ISO image or the
provider did not get a response in 5 minutes from BIOS on successful boot to ISO
image.
Recommended
Response Action
1) Make sure that a POST error did not result in user interaction (Press F1 to
continue or F2 to run BIOS setup). 2) Reset iDRAC and rerun the command.
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
OSD22
Message Unable to detach ISO image from the host.
Detailed
Description
Unable to detach ISO image from the host because either the image is already
detached, or iDRAC may not be operating normally.
Recommended
Response Action
1) Rerun the command. 2) Reset iDRAC
Category Configuration (OSD = OS Deployment)
Severity Severity 1 (Critical)
No alerts are applicable for this message
OSD23
Message Unable to continue with DetachISOImage - another command is in the process of
exposing the ISO Image and booting to it.
Detailed
Description
Cannot continue with DetachISOImage because another command is in the
process of exposing the ISO image and booting to it.
Recommended
Response Action
See the ConcreteJob status to make sure that the current running process is
complete and then run DetachISOImage.
828