Reference Guide

Table Of Contents
MEM9004
Message Intel QPI interconnect arg1 has degraded.
Arguments arg1 = QPI link number
Detailed
Description
A link degradation was detected in propagation of signals between processors
through the Intel QPI interconnect interconnect identified in the message. The
system will continue to operate at reduced performance.
Recommended
Response Action
Do one of the following: 1) Restart the server and check whether the issue persists.
2) If the issue is not resolved by the preceding action, reseat the processors and
restart the server. 3) If the issue persists, contact your service provider.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Intel QPI interconnect <number> has degraded. Reseat processor.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM9005
Message Intel SMI 2 Memory interconnect arg1 has degraded.
Arguments arg1 = link number
Detailed
Description
A link degradation was detected in propagation of signals between processor and
memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended
Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the
issue is not resolved by preceding action, reseat the processor and restart the
server. 3) If the issue persists, contact your service provider.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Intel SMI 2 interconnect <number> degraded. Reseat memory riser.
802