Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM1212
Message Memory redundancy is lost.
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM1214
Message Memory redundancy is degraded.
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 2 (Warning)