Reference Guide

Table Of Contents
Detailed
Description
The contents of the PKCS12 parameter was not valid because: 1) not a valid PKCS12
file 2) not a valid pfx file 3) did not contain a valid key.
Recommended
Response Action
Validate that the PKCS12 file was Base64 encoded. OpenSSL can be used to create
or validate a PKCS12 file.
Category Configuration (LC = Lifecycle Contr)
Severity Severity 2 (Warning)
No alerts are applicable for this message
LC022
Message Lifecycle Controller Log Export was successful.
Detailed
Description
The Lifecycle Controller Log was successfully exported to the destination specified.
Recommended
Response Action
No response action is required.
Category Configuration (LC = Lifecycle Contr)
Severity Severity 3 (Informational)
No alerts are applicable for this message
LC023
Message Cannot access network share.
Detailed
Description
Credentials or network share identity information provided did not result in a
network connection being established.
Recommended
Response Action
Check network share access credentials (IP address, user name, password, share
type, and so on). Refer to Lifecycle Controller Profile documentation for more
details.
Category Configuration (LC = Lifecycle Contr)
Severity Severity 2 (Warning)
No alerts are applicable for this message
LC024
Message Unable to retrieve Lifecycle Controller Log records.
Detailed
Description
Unable to retrieve Lifecycle Controller Log records because of an issue internal to
the firmware.
Recommended
Response Action
Do one of the following: 1) Try the operation again 2) AC power cycle the system 3)
apply the latest firmware update packages for Lifecycle Controller and iDRAC.
705