Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV119
Message PCIe ride-through mode is disabled.
Detailed
Description
The Chassis Management Controller (CMC) has disabled PCIe ride-through mode.
PCIe adapters that are turned on and in "ride-through" mode are immediately
turned off.
Recommended
Response Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV120
Message PCIe ride-through mode is enabled.
Detailed
Description
The Chassis Management Controller (CMC) has enabled PCIe ride-through mode.
PCIe adapters will remain turned on for the number of seconds specified by the
ride-through timeout value after the server they are assigned to is turned off.
Recommended
Response Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
669