Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV117
Message arg1 arg2 was unassigned/unmapped from server- arg3 .
Arguments arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server
number
Detailed
Description
The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been
unassigned/unmapped from the server identified in the message.
Recommended
Response Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV118
Message Fabric arg1 is down.
Arguments arg1 = fabric ID
Detailed
Description
The Fabric identified in the message is not up and a chassis power cycle is required.
Recommended
Response Action
Power cycle the chassis. Using the Chassis Management Controller (CMC)
RACADM command line interface, run the command "racadm chassisaction
powercycle".
Category System Health (IOV = IO Virtualization)
Severity Severity 1 (Critical)
Trap/EventID 2553
668