Reference Guide

Table Of Contents
Arguments arg1 = number of watts
Detailed
Description
The discovery process for PCIE adapters was unable to allocate the power required
to power on the PCIE adapters
Recommended
Response Action
Using the Chassis Management Controller (CMC) RACADM command line
interface, run the command "racadm config -g cfgChassisPower -o
cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional
power supply.
Category Configuration (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 10746
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV116
Message PCIE AUX power cable arg1 .was disconnected while powered on.
Arguments arg1 = cable number
Detailed
Description
The Chassis Management Controller (CMC) detected a power fault in an PCIE AUX
power cable after the adapter was powered on. A power fault may be caused by a
loose cable connection to the adapter or between the cable and the AUX cable
harness.
Recommended
Response Action
Make sure AUX power cable identified in the message is fully plugged into the
adapter and the AUX cable harness.
Category System Health (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 2554
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
667