Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * * *
IOV108
Message Power fault detected on PCIE adapter arg1 in arg2 arg3 .
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed
Description
The Chassis Management Controller (CMC) detected a power fault in an adapter
after the adapter was powered on. A power fault may be caused by a damaged
adapter or the adapter power requirements exceed the maximum power limits of
the slot.
Recommended
Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the
PCIe slot. For a list of supported devices, contact your service provider.
Category System Health (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 2554
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * * *
IOV109
Message An error condition associated with the PCIe slot is cleared.
Detailed
Description
An error condition associated with the PCIe slot is cleared.
Recommended
Response Action
No response action is required.
663