Reference Guide

Table Of Contents
Recommended
Response Action
Using the Chassis Management Controller (CMC) RACADM command line
interface, run the command "racadm config -g cfgChassisPower -o
cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional
power supply.
Category System Health (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 2554
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * * *
IOV105
Message Unable to manage PCIE adapter arg1 located in arg2 arg3 .
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed
Description
An error by the Chassis Infrastructure slot management detected an error which
may prevent the physical assignment/unassignment or power off of a slot. The
errors may be caused by PCIE training timeouts, false hot plug signals, or
installation of an unsupported PCIe adapter card. For a list of supported PCIe
adapter cards contact your service provider.
Recommended
Response Action
Make sure that supported adapters are used and installed correctly in the PCIe slot.
Category System Health (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 2554
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
661