Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV103
Message A PCIe adapter arg1 in arg2 arg3 is replaced by PCIe adapter arg4 .
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number, arg4 = device name
Detailed
Description
The Chassis Management Controller (CMC) detected the replacement of an
adapter in the slot identified in the message.
Recommended
Response Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * * *
IOV104
Message The Chassis Management Controller (CMC) is unable to allocate arg1 Watt for
server- arg2 PCIe adapters.
Arguments arg1 = number of Watt, arg2 = server slot number
Detailed
Description
For each adapter assigned to a server, power is allocated when the server is turned
on. If the available power is less than the required power, the Chassis Management
Controller (CMC) will not power on the adapters associated with the server.