Reference Guide

Table Of Contents
IOV101
Message A PCIe adapter arg1 is inserted in arg2 arg3 .
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed
Description
The Chassis Management Controller (CMC) detected the insertion of an adapter in
the slot identified in the message.
Recommended
Response Action
If the adapter in slot identified in the message is mapped to a server, the server
must be turned off then back on before server can access adapter. If the adapter in
slot is a shared adapter and any server is on then the entire chassis must be turned
off and turned on for the server(s) to gain access to the installed shared adapter.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV102
Message A PCIe adapter arg1 is removed from arg2 arg3 .
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed
Description
The Chassis Management Controller (CMC) detected the removal of an adapter
card from the slot identified in the message.
Recommended
Response Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747