Reference Guide

Table Of Contents
Recommended
Response Action
Turn off all servers that the PCIe slots or virtual adapter (VA) will be assigned-to and
unassigned-from, and then retry the operation.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
IOV012
Message Unable to assign a virtual adapter (VA) to a non-default server because a license is
required.
Detailed
Description
By default, the non-licensed system assigns virtual adapters (VA) 1-4 to servers 1-4
respectively.
Recommended
Response Action
Import a license which enables the assignment of a PERC virtual adapter (VA) to
any server. For more information about licenses, contact your service provider.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
IOV013
Message Unable to assign a virtual adapter (VA) to a server that is already assigned a VA,
because a server may be assigned only one VA.