HWC5037
Message I/O module arg1 failed to boot.
Arguments arg1 = number
Detailed
Description
The firmware on the I/O module did not boot. The problem may be because the
I/O module is not inserted correctly.
Recommended
Response Action
Reseat I/O module. If problem persists, contact the service provider.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
HWC6000
Message The arg1 controller is offline.
Arguments arg1 = name
Detailed
Description
Information and status from the controller is unavailable.
Recommended
Response Action
Remove and reapply input power. If problem persists, contact technical support.