Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
HWC5035
Message An over-temperature event detected on I/O module arg1 .
Arguments arg1 = number
Detailed
Description
The I/O module over heated.
Recommended
Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check
the temperature sensor status for the chassis and make sure it is within the chassis
operating temperature range. 3) Reseat the I/O module to clear the over-
temperature condition. If the problem persists, contact the service provider.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
HWC5036
Message A failure is detected on IO module arg1 .
Arguments arg1 = number
Detailed
Description
The IOM module performance may be impact.
Recommended
Response Action
Contact technical support. Refer to your product documentation to choose the
contact method that is convenient for you.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
616