Reference Guide

Table Of Contents
FLDC1028
Message OMSS Connection to Fluid Cache service is no longer present.
Detailed
Description
The communications connection between OMSS and the Fluid Cache service is no
longer present.
Recommended
Response Action
To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is
running. To verify the service run the following command: "fldc --status". 2) Re-
establish the connect by running the following command: :"omconfig storage
fluidcache action=connect"
Category Storage (FLDC = Unknown)
Severity Severity 1 (Critical)
OMSA Event ID 2699
OMSA Trap ID 160400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FLDC1029
Message There are not enough journal mirrors available for Fluid Cache to operate.
Detailed
Description
The message indicates that there are not enough journal mirrors available for Fluid
Cache to operate. Make sure that there are at least two journal mirrors that are
accessible. Activate either one or more failed cache devices or use the fldc_restore
utility to rebuild the node.
Recommended
Response Action
Contact your service provider to diagnose the cause and assist in recovery process.
Category Storage (FLDC = Unknown)
Severity Severity 1 (Critical)
OMSA Event ID 2703
OMSA Trap ID 160400
555