Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FLDC1020
Message The storage device with WWN = arg1 and path = arg2 is in unknown state.
Arguments arg1 = wwn name, arg2 = path name
Detailed
Description
The storage device identified in the message is in unknown state.
Recommended
Response Action
Service is required. Contact your service provider.
Category Storage (FLDC = Unknown)
Severity Severity 2 (Warning)
OMSA Event ID 2909
OMSA Trap ID 120300;150300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FLDC1021
Message The journal mirror entry with WWN = arg1 is not accessible.
Arguments arg1 = World Wide Name
Detailed
Description
The device identified in the message having the journal mirror entry with given
WWN (World Wide Name) is not accessible. A portion of an SSD is used for journal
content. To assure consistency, the journal content is written into two other SSDs.
These copies are journal mirrors. If the journal content cannot be written to any of
the journal mirrors, then this event is signaled. It is a warning because the FLDC
code will then attempt to choose another SSD to be a journal mirror.
Recommended
Response Action
No response action is required..
550