Reference Guide

Table Of Contents
No alerts are applicable for this message
FC017
Message Unable to perform the operation due to an internal error in iDRAC.
Detailed
Description
An internal error occurred in iDRAC and the operation cannot continue. An iDRAC
reset is required to recover from the error.
Recommended
Response Action
Disconnect the AC power source from the system, reconnect the power source,
and retry the operation.
Category Configuration (FC = Fiber Channel)
Severity Severity 1 (Critical)
No alerts are applicable for this message
FC102
Message The FC arg1 port arg2 link is not functioning either because the FC cable is not
connected or the FC device is not functioning.
Arguments arg1 = controller ID, arg2 = port ID
Detailed
Description
The FC controller port link identified in the message is not functioning either
because the FC cable is not connected or the FC device is not functioning.
Recommended
Response Action
Do the following: 1) Make sure that the FC port is enabled. 2) Make sure the
Activity/Speed LEDs are lit if the physical port has LEDs. 3) Check the FC cable and
FC cable connections for proper installation. 4) Check that the attached FC switch
is functioning.
Category System Health (FC = Fiber Channel)
Severity Severity 2 (Warning)
Trap/EventID 2538
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
534