Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FAN903
Message Cannot enable the Enhanced Cooling Mode because an unsupported fan is
inserted in the Chassis.
Detailed
Description
The Enhanced Cooling Mode cannot be enabled because an unsupported fan is
present in the Chassis.
Recommended
Response Action
Insert a fan that is supported by the Chassis, and then retry the operation. For a list
of fans that are supported by Chassis, see the Chassis Management Controller
Users Guide.
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FAN904
Message Cannot enable the Enhanced Cooling Mode because the Maximum Power
Conservation Mode is enabled.
Detailed
Description
The Enhanced Cooling Mode cannot be enabled because the Maximum Power
Conservation Mode is enabled.
Recommended
Response Action
Disable the Maximum Power Conservation Mode, and then retry the operation. To
disable the mode by using CMC Web interface, click Chassis Overview > Power >
Configuration. To disable the mode using the RACADM utility, run the command
"racadm config -g cfgThermal -o cfgThermalEnhancedCoolingMode 0".
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
524