Reference Guide

Table Of Contents
FAN901
Message The Enhanced Cooling Mode is successfully disabled.
Detailed
Description
The Enhanced Cooling Mode is successfully disabled.
Recommended
Response Action
No response action required.
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FAN902
Message Cannot enable the Enhanced Cooling Mode because sufficient power is not
available.
Detailed
Description
The Enhanced Cooling Mode cannot be set because required power is not
available.
Recommended
Response Action
Add PSUs with higher power capability or remove Chassis components such as I/O
Modules or servers until the power requirements have been lowered enough to
enable the Enhanced Cooling Mode, and then retry the operation.
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
523