Reference Guide

Table Of Contents
FAN8501
Message Enhanced Cooling Mode is Disabled
Detailed
Description
Disabling Enhanced Cooling Mode allows for reduced power consumption by
reducing the maximum speed of the blowers while still providing sufficient blade
airflow.
Recommended
Response Action
No response action is required.
Category Audit (FAN = Fan Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
FAN8502
Message Unable to detect the blower arg1 because the blower may not be optimally
operating.
Arguments arg1 = blower name
Detailed
Description
The current CMC firmware did not detect the blower identified in the message.
Recommended
Response Action
Make sure that CMC is using the latest firmware, and then retry the operation.
Category Audit (FAN = Fan Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FAN8503
Message The Chassis was turned off because more than two internal fans stopped
functioning.