Reference Guide

Table Of Contents
Recommended
Response Action
Remove and re-install the fan, or replace the fan with a new fan. If the issue
persists, contact your service provider.
Category System Health (FAN = Fan Event)
Severity Severity 1 (Critical)
OMSA Event ID 5104
OMSA Trap ID 5104
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
FAN0027
Message The arg1 sensor has failed with a value of arg2 RPM.
Arguments arg1 = sensor name, arg2 = fan speed
Detailed
Description
The sensor identified in the message has failed. The sensor may be required for
optimal system performance.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults.
If the fan sensor has failed, replace the system board. For more information,
contact your service provider.
Category System Health (FAN = Fan Event)
Severity Severity 1 (Critical)
OMSA Event ID 5105
OMSA Trap ID 5105
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
518