Reference Guide

Table Of Contents
EPP014
Message Unable to use the Extended Power Performance (EPP) feature because the
Redundancy Policy is not set to Grid Redundancy.
Detailed
Description
The Extended Power Performance is cannot be used because the Redundancy
Policy is not set to Grid Redundancy.
Recommended
Response Action
Configure the Power Redundancy Policy to Grid Redundancy and retry to enable
the EPP feature. To configure the Power Redundancy Policy using the RACADM
CLI utility, enter the following command: "racadm config -g cfgChassisPower -o
cfgChassisRedundancyPolicy 1".
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP015
Message Unable to use the Extended Power Performance (EPP) feature because the System
Input Power Cap is set to less than or equal to 13300W (45381 BTU/h).
Detailed
Description
The Extended Power Performance cannot be used because the System Input
Power Cap is set to less than or equal to 13300W (45381 BTU/h).
Recommended
Response Action
Set the Chassis Power Cap to greater than 13300W (45381 BTU/h), and then retry
to use the EPP feature. To set the Chassis Power Cap using the RACADM CLI utility,
enter the following command: "racadm config -g cfgChassisPower -o
cfgChassisDefaultPowerCapUpperBound 13301".
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
501