Description
The Extended Power Performance cannot be used because the power supply unit
(PSU) slot identified in the message has no output power.
Recommended
Response Action
Make sure that the PSU in the PSU slot has no issue in the output power, and then
retry to enable the EPP feature. To check the health status of the PSU identified in
the message using the RACADM CLI utility, enter the following command: "racadm
getpbinfo". If the PSU identified in the message is showing no output power,
contact your service provider.
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP013
Message Unable to use the Extended Power Performance (EPP) feature because the power
rating of power supply unit (PSU) slot - arg1 is less than 3000W.
Arguments arg1 = slot number
Detailed
Description
The Extended Power Performance cannot be used because the power rating of
PSU identified in the slot is less than 3000W.
Recommended
Response Action
Make sure that there are atleast six PSUs in the chassis and each PSU must be of
3000W capacity, and then retry to enable the EPP feature.
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)