Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP009
Message Unable to use the Extended Power Performance (EPP) feature because the Grid
Redundancy feature is not available.
Detailed
Description
The Extended Power Performance cannot be used because the Grid Redundancy
feature is not available.
Recommended
Response Action
Resolve the Grid Redundancy feature-related issue, and then retry to enable the
EPP feature. For more information on the Grid Redundancy feature see Chassis
Management Controller (CMC) User Guide.
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP010
Message Unable to use the Extended Power Performance (EPP) feature because the power
supply unit (PSU) slot - arg1 is empty.
Arguments arg1 = slot number
Detailed
Description
The Extended Power Performance cannot be used because the power supply unit
(PSU) slot identified in the message is empty.
Recommended
Response Action
Install an EPP-capable PSU in the empty slot, and then retry to enable the EPP
feature.
498