Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP003
Message Unable to use the Extended Power Performance (EPP) feature because the
Dynamic Power Supply Engagement mode is enabled.
Detailed
Description
The Extended Power Performance cannot be used because the Dynamic Power
Supply Engagement mode is enabled.
Recommended
Response Action
Disable the Dynamic Power Supply Engagement mode and then retry to enable the
EPP feature.
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
EPP004
Message Unable to use the Extended Power Performance (EPP) feature because the Server
Performance Over Power Redundancy mode is enabled.
Detailed
Description
The Extended Power Performance cannot be used because the Server
Performance Over Power Redundancy mode is enabled.
Recommended
Response Action
Disable the Server Performance Over Power Redundancy mode and then retry to
enable the EPP feature.
Category System Health (EPP = Extended Power Performance)
Severity Severity 2 (Warning)
495