Message Communication timeout on arg1 .
Arguments arg1 = Enclosure Name
Detailed
Description
The controller is unable to communicate with an enclosure. There are several
reasons for communication loss. For example, there may be a bad or loose cable.
An unusual amount of I/O may also interrupt communication with the enclosure.
In addition, communication loss may be caused by software, hardware, or firmware
problems, bad or failed power supplies, and enclosure shutdown.
Recommended
Response Action
Check for problems with the cables. See the Cables attached correctly section for
more information on checking the cables. You should also check to see if the
enclosure has degraded or failed components. To do this, select the enclosure
object in the tree view and click the Health subtab. The Health subtab displays the
status of the enclosure components. Verify that the controller has the supported
driver and firmware versions installed and that each Enclosure Management
Modules (EMMs) are running the same version of supported firmware.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
OMSA Event ID 2137
OMSA Trap ID 85300