Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC4
Message arg1 firmware mismatch.
Arguments arg1 = Enclosure Name
Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both
modules have the same version of the firmware. This alert may be caused when
you attempt to insert an EMM module that has a different firmware version than an
existing module.
Recommended
Response Action
Download the same version of the firmware to both EMM modules.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
OMSA Event ID 2120
OMSA Trap ID 85300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC40
Message A new enclosure was detected on arg1 .
Arguments arg1 = controller name
Detailed
Description
The controller detected a new enclosure. This is due either to a hot plug of an
enclosure, or a power state change of an enclosure. In addition, this message is
generated if the daisy chain order of the enclosures changes.
Recommended
Response Action
No response action is required.
489