Reference Guide

Table Of Contents
ENC27
Message SAS or SATA mixing of physical disks is not supported within the arg1 .
Arguments arg1 = Enclosure Name
Detailed
Description
The enclosure cannot support both SAS and SATA physical disks. Physical disks
may be disabled. This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage (ENC = Storage Enclosr)
Severity Severity 3 (Informational)
Trap/EventID 4339
OMSA Event ID 2303
OMSA Trap ID 85100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC28
Message Enclosure Management Module (EMM) firmware version mismatch detected in
arg1 . arg2 arg3 .
Arguments arg1 = enclosure name, arg2 = EMM 0 version, arg3 = EMM 1 version
Detailed
Description
The firmware on the EMM modules is not the same version. Both modules must
have the same firmware version. This message is caused when you attempt to
insert an EMM module that has a different firmware version than an existing
module.
Recommended
Response Action
Upgrade to the same version of the firmware on both EMM modules and then
powercycle the system and attached enclosures.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
484