Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC24
Message Communication with arg1 is intermittent.
Arguments arg1 = enclosure name
Detailed
Description
The controller is not receiving a consistent response from the enclosure. There
could be a firmware problem or an invalid cabling configuration. If the cables are
too long, they degrade the signal.
Recommended
Response Action
Power down all enclosures attached to the system and reboot . If the problem
persists, upgrade the firmware to the latest supported version. Verify the cable
configuration is valid. See the storage hardware documentation for valid cabling
configurations.
Category Storage (ENC = Storage Enclosr)
Severity Severity 1 (Critical)
Trap/EventID 4337
OMSA Event ID 2268
OMSA Trap ID 10400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC25
Message arg1 has a hardware error.
Arguments arg1 = enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state.
Recommended
Response Action
Verify the health of the enclosure and its components. See the storage hardware
documentation for more information. Contact technical support.
482