Reference Guide

Table Of Contents
Severity Severity 3 (Informational)
Trap/EventID 4339
OMSA Event ID 2152
OMSA Trap ID 85100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC100
Message arg1 is sending inconsistent responses to the controller.
Arguments arg1 = enclosure name
Detailed
Description
The storage controller is not receiving a consistent response from the enclosure
due to a firmware problem or an incorrect cabling configuration. If the cables are
longer than the specified maximum length, the signals may be degraded.
Recommended
Response Action
Turn off all the enclosures attached to the system, check if the cable configurations
are correct and reboot the system. If the problem persists, update the enclosure
firmware to the latest supported version. Download the latest supported version of
the firmware from the service provider. For more information about cable
configuration, see storage enclosure documentation.
Category Storage (ENC = Storage Enclosr)