Reference Guide

Table Of Contents
Recommended
Response Action
Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG8160
Message PERC Battery arg1 - incorrect status = arg2 \n arg3 .
Arguments arg1 = PERC Controller Location, arg2 = 80000000000000??, arg3 = Error
Reason
Detailed
Description
Recommended
Response Action
"If <Error Reason> is (Battery missing or disconnected) then check the battery cable
to the PERC controller. If <Error Reason> is (Replace battery pack) then replace
battery pack. If <Error Reason> is (Remaining capacity low) then battery pack may
need to be replaced soon."
Category Storage (DIAG = Diagnostic)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
450