Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0155
Message Hard Drive - Not installed.
Detailed
Description
Recommended
Response Action
Power down system and check the signal and power connections to the hard
drive. Rerun the diagnostic. If no error occurs then it was a cable or connector
issue. This error is issued for notebooks which must have a hard disk so it is an
error if not found.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
No alerts are applicable for this message
DIAG0212
Message System board - CMOS, Location = arg1 h, Expected = arg2 h, Found = arg3 h.
Arguments arg1 = Hex, arg2 = Hex, arg3 = Hex
Detailed
Description
Recommended
Response Action
Make sure that the system is running with the latest BIOS and rerun the diagnostics.
Category System Health (DIAG = Diagnostic)
Severity Severity 1 (Critical)
No alerts are applicable for this message
DIAG0213
Message System board - CMOS battery failure detected.
423