Reference Guide

Table Of Contents
Recommended
Response Action
Hard drives on desktops should be found if connected to the chipset disk
controller but PERC/SCU/SAS Adapters are not supported by legacy ePSA so if the
hard drive is connected to these controllers this message is just a warning. If the
system has a hard disk connected to the System Board chipset disk controller,
power down the system and check the signal and power connections to it. Rerun
the diagnostic. If no error occurs then it was a cable or connector issue.
Category Storage (DIAG = Diagnostic)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0151
Message Hard Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 .
Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = 80000000000000??, arg4 =
Error Reason
Detailed
Description
Recommended
Response Action
SMART Predictive Failure indicates the hard drive has failed SMART and maybe
nearing the end of its life. Other types of <Error Reason> in this category may
indicate an intermittent or firmware problem, rerun the test again. Desktops,
servers: Check the hard disk drive cables and connections. All systems: If error
persists, make sure that hard disk drive firmware and BIOS are current. The
<80000000000000??> value is an EFI error code returned by the driver.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
421