Reference Guide

Table Of Contents
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0146
Message Hard Drive arg1 - S/N arg2 , self test log contains previous error(s).
Arguments arg1 = Drive Location, arg2 = Serial Number
Detailed
Description
Prior failure checking removed, is now obsolete.
Recommended
Response Action
No response action is required.
Category Storage (DIAG = Diagnostic)
Severity Severity 3 (Informational)
No alerts are applicable for this message
DIAG0147
Message Optical Drive arg1 - Self test: arg2 .
Arguments arg1 = Nth Drive, arg2 = Error Reason
Detailed
Description
Recommended
Response Action
This typically is a user error since these drives can be disconnected from the
system. If disconnected, reconnect the optical drive to system board. Check BIOS
setup to make sure the SATA port the drive is connected and has not been
disabled. Rerun the diagnostic. If errors persist the optical drive is defective.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)