Reference Guide

Table Of Contents
DIAG0141
Message Hard Drive - No Hard Drive detected.
Detailed
Description
Recommended
Response Action
Hard drives are not required on all systems so this message is usually a warning.
Desktops and Servers: If the system has a hard disk, power down system and check
the signal and power connections to it. Rerun the diagnostic. If no error occurs
then it was a cable or connector issue.
Category Storage (DIAG = Diagnostic)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0142
Message Hard Drive arg1 - S/N arg2 , arg3 self test unsuccessful arg4 .
Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = DST Short, DST Long, arg4 =
Error Reason
Detailed
Description
Recommended
Response Action
If <Error Reason> is "terminated" then the disk controller terminated the test so a
retry of the test is advisable. Otherwise the hard drive should be replaced. {In the
factory, this test type may also be DEFT, in addition to DST Short and DST Long.
The "terminated" case should not occur in the field, only in development due to
software issues}
Category Storage (DIAG = Diagnostic)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
417