Reference Guide

Table Of Contents
DIAG0123
Message UEFI: Memory error detected. :OR: LEGACY: Memory - integrity test discrepancy.
Detailed
Description
Recommended
Response Action
MemRX not enabled or not supported. Servers UEFI: Power down system and re-
seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue.
Client LEGACY: Power down system and re-seat DIMMS. Retry test and if no error
occurs it was a DIMM connection issue. Check for latest BIOS.
Category System Health (DIAG = Diagnostic)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0124
Message arg1 , arg2
Arguments arg1 = Timestamp, arg2 = Log message
Detailed
Description
Log message is different for the log type supported by the system. An IPMI log may
refer to "SEL", other log types also exist.
Recommended
Response Action
Depends on <Log message>.
Category System Health (DIAG = Diagnostic)