Reference Guide

Table Of Contents
Trap/EventID 4329
OMSA Event ID 2316
OMSA Trap ID 75400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
CTL45
Message Single-bit ECC error on arg1 .
Arguments arg1 = Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is beginning to malfunction.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data
corruption. The DIMM is a part of the controller battery pack. Refer to hardware
documentation for information on replacing the DIMM.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
OMSA Event ID 2319
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
370