CTL11
Message Configuration on arg1 was reset.
Arguments arg1 = controller name
Detailed
Description
A user operation to reset the controller configuration was performed.
Recommended
Response Action
No response action is required.
Category Storage (CTL = Storage Contr)
Severity Severity 3 (Informational)
Trap/EventID 4331
OMSA Event ID 2157
OMSA Trap ID 75100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
CTL12
Message An invalid SAS configuration has been detected on arg1 . Details: arg2
Arguments arg1 = Controller name, arg2 = error message
Detailed
Description
The controller and attached enclosures are not cabled correctly.
Recommended
Response Action
Refer to the storage hardware documentation for information on correct cabling
configurations.
Category Storage (CTL = Storage Contr)
Severity Severity 1 (Critical)
Trap/EventID 4329
OMSA Event ID 2182
OMSA Trap ID 75400