Reference Guide

Table Of Contents
CPU0704
Message CPU arg1 machine check error detected.
Arguments arg1 = number
Detailed
Description
System event log and OS logs may indicate that the exception is external to the
processor.
Recommended
Response Action
1) Check system and operating system logs for exceptions. If no exceptions are
found continue. 2) Turn system off and remove input power for one minute. Re-
apply input power and turn system on. 3) Make sure the processor is seated
correctly. 4) If the issue still persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> machine check error detected. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CPU0800
Message CPU arg1 voltage regulator module is present.
Arguments arg1 = number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health (CPU = Processor)
Severity Severity 3 (Informational)
Trap/EventID 2243
325