Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CPU0003
Message CPU arg1 is stuck in POST.
Arguments arg1 = number
Detailed
Description
None
Recommended
Response Action
1) Turn off the server and disconnect input power for one minute. Re-apply input
power and turn system on. 2) Reduce system configuration to minimum memory
and remove all PCI devices. If system completes POST, update system BIOS. Re-
install memory and PCI one component at a time to meet the original
configuration. 3) If the issue still persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CPU0004
Message CPU arg1 failed to initialize.
Arguments arg1 = number
Detailed
Description
None
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is inserted correctly, if the
processor is removable. 3) If the issue still persists, contact technical support. Refer
to the product documentation to choose a convenient contact method.
314