CMC8605
Message The chassis health state is no longer OK and is currently arg1 .
Arguments arg1 = health state
Detailed
Description
The chassis health state is no longer OK and is currently the state identified in the
message. Actions should be taken to resolve any outstanding issues so that the
chassis health state will return to OK.
Recommended
Response Action
Review the Chassis log or the Chassis Management Controller(CMC) SEL log for
any outstanding issue(s) and resolve any issues found by performing the
recommended response action for each issue found. If the issue persists, export
the chassis log and CMC SEL log and contact your support provider.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
CMC8700
Message The I/O Module in slot arg1 is configured in secure IOM mode.
Arguments arg1 = slot number
Detailed
Description
I/O Module identified in the message cannot be managed from the CMC when the
I/O Module is configured in secure IOM mode.
Recommended
Response Action
No response action is required.
Category Configuration (CMC = Chassis Management Controller)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
310