Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
CMC8547
Message Missing kernel module arg1 . Failover condition detected
Arguments arg1 = module name
Detailed
Description
A firmware error occurred causing the failover. If this condition continues, a
failover will result. If multiple failovers occur, contact Service.
Recommended
Response Action
No response action is required. If the issue persists, contact your service provider.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
CMC8548
Message The active Chassis Management Controller is no longer connected to an external
network.
Detailed
Description
The active Chassis Management Controller is not connected to an external
network for more than 25 seconds. A failover is performed if the standby CMC is
connected to the external network.
Recommended
Response Action
Make sure that the external network cable is connected to the active CMC and the
network switch. If the issue persists, contact your service provider.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
294