Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8535
Message Unable to turn on High Power Management for the server arg1
Arguments arg1 = slot number
Detailed
Description
Unable to turn on the server specified in the message because of an internal CMC
error.
Recommended
Response Action
Reboot CMC and retry the operation. If the issue persists, reseat the server and
retry the operation.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 8689
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8538
Message Firmware version string is too long.
Detailed
Description
The length of the CMC firmware version to be sent in the message from local CMC
to peer CMC is too long. Under these conditions, CMC version in the message is
displayed as 1.0.
Recommended
Response Action
No response action is required.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 3 (Informational)