Reference Guide

Table Of Contents
CMC8533
Message Unable to read the FRU information, status = arg1
Arguments arg1 = status value
Detailed
Description
Unable to read the header of the extended FRU information. This can occur if there
is a problem in the communication between the CMC and the server.
Recommended
Response Action
Remove and reinsert the server. The CMC will retry the read operation of the FRU
information. If the issue persists, contact your service provider.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
CMC8534
Message Unable to turn on the server arg1 because the power requirement request exceeds
the power cap value.
Arguments arg1 = slot number
Detailed
Description
Unable to turn on the server specified in the message, because the available power
is lesser than the requested power.
Recommended
Response Action
In the CMC Web interface, verify the available power and server power
requirements. If sufficient power is available, retry the operation. Otherwise,
increase the power cap value.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 2546
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
288